7 Configuration
7.1 Delivery state
On delivery, the safety laser scanner is in a safe state.
•
T
he operational status of the safety laser scanner is Waiting for configuration.
•
The 7-segment display indicates .
7.2 CDS
You will require a CDS (Configuration & Diagnostic Software) to configure and diagnose
f
aults with these devices.
Approach
1. Open the download web page by entering CDS in the search field on
www.sick.com.
2. Take note of the system requirements on the download page.
3. Download the installation file from the download page. Extract it and run it.
4. Follow the notes from the setup assistant.
7.3 Preparing the configuration
Overview
All a
vailable parameters can be configured using the CDS (Configuration & Diagnostic
Software). The field geometries for the protective fields and warning fields can also be
defined in the CDS.
There are two options for connecting the CDS to the device:
•
Local device connection
•
Network
The connection to the local configuration and diagnostics connection is made using a
service cable that is available as an accessory.
Configuration via the network is only possible after the PROFINET configuration. The
CDS is opened using TCI in the hardware configuration in the network engineering tool.
CONFIGURATION 7