Further topics
•
"Mount
ing", page 50
•
"Commissioning", page 88
3.2 Product characteristics
3.2.1 Specific features
•
190° sc
anning angle
•
Increased dust and particle tolerance due to dazzle and particle algorithms
•
Sensor heads with a scanning range up to 4 m, 5.5 m or 7 m (maximum radii of
the protective field)
•
Warning field range: 49 m (20 m at 20% radiance factor)
•
Various I/O modules for different fields of applications
•
Easy exchange of the I/O module. This makes it easy to extend the functionality.
•
Configuration via PC or notebook using the SICK Configuration & Diagnostic soft‐
ware
•
Power supply plug with integrated configuration memory
•
Dual field mode with field sets comprising a protective field and a warning field
•
Dual protective field mode with field sets comprising 2 protective fields (optional
simultaneous monitoring of 2 field sets = 4 protective fields)
•
Triple field mode with field sets comprising one protective field and 2 warning
fields
•
Contour monitoring of a protective field
•
Integrated configurable restart interlock/restart delay
•
Simultaneous protective fields with separate output information, and ability to
reset separately
•
Direct safety-related connection to PROFINET IO networks
•
Connection options:
°
S3000 PROFINET IO: RJ-45 female connectors for RJ-45-push-pull male con‐
nector
°
S3000 PROFINET IO-OF: SCRJ female connectors for VARIOSUB push-pull
SCRJ plug connector
•
Monitoring case switching via static inputs
S3000 PROFINET IO/IO-OF Advanced
•
Up to 4 field sets
S3000 PROFINET IO/IO-OF Professional
•
Up to 8 field sets
The S3000 PROFINET IO/IO-OF has no local inputs or outputs apart from the parame‐
terization interface. All communication occurs via the PROFINET IO network.
3.2.2 Device overview
The safety laser scanner comprises 3 components:
•
T
he sensor head with the opto-electronic detection system
•
The I/O module that determines the functionality of the device
•
The system plug with configuration memory. The system plug has all the electrical
connections except for the configuration interface.
PRODUCT DESCRIPTION 3
8013291/ZA19/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
15
Subject to change without notice