EasyManuals Logo

SICK S3000 PROFINET IO User Manual

SICK S3000 PROFINET IO
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
2 Safety information
2.1 General safety notes
This chapter contains general safety information about the safety laser scanner.
F
urther safety information regarding specific usage situations is provided in the respec‐
tive chapters.
WARNING
Ine
ffectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
b
Please read this document carefully and make sure that you understand the con‐
tent fully before working with the device.
b
Follow all safety notes in this document.
Laser class 1
CAUTION
If an
y operating or adjusting devices other than those specified in this document are
used or other methods are employed, this can lead to dangerous exposure to radiation.
b
Only use the operating or adjusting devices specified in this document.
b
Only follow the methods specified in this document.
b
Do not open the housing, except for the purposes of the installation and mainte‐
nance work specified in these operating instructions.
Figure 1: Laser class 1
T
his device complies with the following standards:
IEC 60825-1:2007
IEC 60825-1:2014
21 CFR 1040.10 and 1040.11, except for changes due to Laser Notice No. 50
dated 24/06/2007
Additional measures to shield the laser beam are not required (eye-safe).
2.2 Intended use
The safety laser scanner is an electro-sensitive protective device (ESPE) and is suitable
f
or the following applications:
Hazardous area protection
Hazardous point protection
Access protection
Mobile hazardous area protection (protection of automated guided vehicles)
The safety laser scanner must only be used within the limits of the prescribed and
specified technical data and operating conditions at all times.
2 SAFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF 8013291/ZA19/2019-11-14 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
Field of view190°
Response time8 ms ... 80 ms
Protection classIP65
Number of simultaneously monitored fields4
Scanning angle190°
Number of inputs2
Number of outputs4
Angular Resolution0.5°
InterfacesPROFINET IO
Operating temperature0 °C ... +50 °C
Resolution for object detection30 mm
Supply voltage24 V DC
TypeLaser Scanner
Operating Voltage24 V DC
Ambient Temperature0 °C ... +50 °C
Storage Temperature–25 °C ... +70 °C
Protective field range0.2 m to 3 m
Protection Field Range0.2 m to 3 m