1. The sequence of instructions for action is numbered.
2.
Follow the order in which the numbered instructions are given.
The check mark denotes the result of an instruction.
7-segment display
Display symbols show the status of the device’s 7-segment display:
Constant display of characters, e.g., 8
Flashing display of characters, e.g., 8
Alternating display of characters, e.g., L and 2
LEDs
LED symbols describe the status of an LED:
O
The LED lights up permanently.
Ö
The LED flashes.
o
The LED is off.
These symbols describe which LED is involved: Ê, Ì, É, Í, Ë
Í Ö
The “Error/Contamination” LED flashes.
Ê O
The “Protective field interrupted” LED lights up permanently.
The term “dangerous state”
T
he figures in this document always show the dangerous state (standard term) of the
machine as movement of a machine part. In practice, there are various types of danger‐
ous state:
Machine movements
Vehicle movements
Live electrical parts
Visible and invisible beams
A combination of multiple hazards
ABOUT THIS DOCUMENT 1
8013291/ZA19/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
9
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
Field of view190°
Response time8 ms ... 80 ms
Protection classIP65
Number of simultaneously monitored fields4
Scanning angle190°
Number of inputs2
Number of outputs4
Angular Resolution0.5°
InterfacesPROFINET IO
Operating temperature0 °C ... +50 °C
Resolution for object detection30 mm
Supply voltage24 V DC
TypeLaser Scanner
Operating Voltage24 V DC
Ambient Temperature0 °C ... +50 °C
Storage Temperature–25 °C ... +70 °C
Protective field range0.2 m to 3 m
Protection Field Range0.2 m to 3 m