Bit Description
Byte 5 5.0 Reserved
5.1 Reserved
5.2 Reserved
5.3 Reserved
5.4 Reserved
5.5 Reserved
5.6 Reserved
5.7 Reserved
12.3 PROFINET diagnostic messages
Operational statuses:
W
aiting for configuration
Lock-out
Device error
Error in the sensor head
Error in the I/O module
Error in the system plug
Measured value error in a 90° segment
Dazzle
Temperature error
Undefined monitoring case
Sequence error in field set switching
Invalid input state
Contamination error or contamination measurement
PROFIsafe communication error
12.4 Data sheet
General details
T
able 27: General details
Minimum Typical Maximum
Type Type 3 (IEC 61496-1)
Safety Integrity Level
1)
SIL2 (IEC 61508)
SIL claim limit
1)
SILCL2 (EN 62061)
Category Category 3 (ISO 13849-1)
Performance level PL d (ISO 13849-1)
PFHd (T
amb
= 25 °C) (me
an probability of a danger‐
ous failure per hour)
8 × 10
–8
T
M
(mis
sion time) 20 years (ISO 13849)
Laser class Laser class 1 (according to IEC 60825-1
a
s well as CDRH 21 CFR 1040.10 and
1040.11; excluded are deviations due to
Laser Notice No. 50 dated June
24, 2007)
Enclosure rating IP65 (EN 60529)
Protection class II (EN 50178)
2)
Operating temperature range –10 °C +50 °C
TECHNICAL DATA 12
8013291/ZA19/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
111
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
BrandSICK
ModelS3000 PROFINET IO
CategoryScanner
LanguageEnglish

Related product manuals