EasyManuals Logo

SICK S3000 PROFINET IO User Manual

SICK S3000 PROFINET IO
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
CAUTION
R
estricted field evaluation in the dual protective field mode
In the Dual protective fields field mode, protective field 2 is not evaluated in the areas in
which a contour is configured as reference.
b
Monitor the contour outside the area of protective field 2.
You define the contour as a reference in the CDS field set editor.
Vertical operation
In v
ertical operation (for access protection and hazardous point protection), the protec‐
tive fields must, in accordance with IEC 61496-3, be configured using the contour as
reference function. In addition, the total response time of the device is not allowed to
exceed 90 ms.
Figure 65: Contour as reference for vertical operation
1
Protective field
2
Contours of the machine opening
3
Contour segment
NOTE
L
ateral, vertical boundaries of the opening (e.g., door frame) together with the floor are
particularly suitable as a reference. If the position of the safety laser scanner is
changed in one or more planes, the distance to the reference changes. The device then
switches its safety outputs to the OFF state or signals Protective field interrupted.
7.11 Monitoring cases
Overview
T
he device supports a configuration with multiple monitoring cases. By switching the
monitoring case you can switch to different monitoring conditions in the case of a
change to the monitoring situation.
CONFIGURATION 7
8013291/ZA19/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
83
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
Field of view190°
Response time8 ms ... 80 ms
Protection classIP65
Number of simultaneously monitored fields4
Scanning angle190°
Number of inputs2
Number of outputs4
Angular Resolution0.5°
InterfacesPROFINET IO
Operating temperature0 °C ... +50 °C
Resolution for object detection30 mm
Supply voltage24 V DC
TypeLaser Scanner
Operating Voltage24 V DC
Ambient Temperature0 °C ... +50 °C
Storage Temperature–25 °C ... +70 °C
Protective field range0.2 m to 3 m
Protection Field Range0.2 m to 3 m

Related product manuals