Mobile hazardous area protection
Mobile ha
zardous area protection is suitable for AGVs (automated guided vehicles),
cranes and forklift trucks, to protect people when vehicles are moving or docking at a
fixed station.
Figure 15: Mobile hazardous area protection: detection of a person when a vehicle approaches
Further topics
"T
iming for monitoring case switching", page 34
3 P
RODUCT DESCRIPTION
26
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF 8013291/ZA19/2019-11-14 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
Field of view190°
Response time8 ms ... 80 ms
Protection classIP65
Number of simultaneously monitored fields4
Scanning angle190°
Number of inputs2
Number of outputs4
Angular Resolution0.5°
InterfacesPROFINET IO
Operating temperature0 °C ... +50 °C
Resolution for object detection30 mm
Supply voltage24 V DC
TypeLaser Scanner
Operating Voltage24 V DC
Ambient Temperature0 °C ... +50 °C
Storage Temperature–25 °C ... +70 °C
Protective field range0.2 m to 3 m
Protection Field Range0.2 m to 3 m