Exporting field sets and fields
1.
Click on Export field sets to XML file.
2. Select the relevant folder and enter a file name for storing the field set informa‐
tion.
3. Start the export.
The field sets and fields will be exported.
7.10.3 Protective field or warning field suggested by the safety laser scanner
The CDS can suggest the protective field or warning field in the field set editor. For this
pur
pose, the safety laser scanner scans the visible surrounding contour several times.
From the data obtained, the CDS suggests the contour and size of the field. The follow‐
ing figure shows an example for the reading of a protective field:
Figure 63: Reading the protective field
In t
hose places at which the surrounding contour is smaller than the maximum protec‐
tive field range (e.g., at 1), the protective field 4 corresponds to the surrounding con‐
tour.
NOTE
T
he measuring error tolerances for the device are automatically subtracted from the
protective field size. As a result the protective field is slightly smaller than the surface
covered 2.
In those places where the surrounding contour is larger than the protective field range
3, t
he protective field corresponds to the possible scanning range.
CONFIGURATION 7
8013291/ZA19/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF
81
Subject to change without notice

Table of Contents

Other manuals for SICK S3000 PROFINET IO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK S3000 PROFINET IO and is the answer not in the manual?

SICK S3000 PROFINET IO Specifications

General IconGeneral
Field of view190°
Response time8 ms ... 80 ms
Protection classIP65
Number of simultaneously monitored fields4
Scanning angle190°
Number of inputs2
Number of outputs4
Angular Resolution0.5°
InterfacesPROFINET IO
Operating temperature0 °C ... +50 °C
Resolution for object detection30 mm
Supply voltage24 V DC
TypeLaser Scanner
Operating Voltage24 V DC
Ambient Temperature0 °C ... +50 °C
Storage Temperature–25 °C ... +70 °C
Protective field range0.2 m to 3 m
Protection Field Range0.2 m to 3 m