Technical Specifications
7-24
ET 200X Distributed I/O Device
EWA 4NEB 780601602-06
Parameters
The following table provides an overview of the parameters you can set for the
basic module.
Table 7-12 Parameters of the BM 143-DESINA FO
Parameters
Range Default Area
S7 slave with
HWCONFIG
Standard slave
with DDB file
SIEM809A.GSG
1
Standard slave
with DDB file
SI03809A.GSG
1
affected
––– ––– DP interrupt mode DPV0/DPV1 DPV1 ET 200X
Diagnostic interrupt Yes/no Yes ET 200X
Hardware interrupt Yes/no Yes ET 200X
––– Enhanced
diagnostics
2
–––
Yes/no Yes ET 200X
––– ––– Startup when
expected/actual
config. differ
Yes/no No ET 200X
Diagnosis: no load voltage (S) Yes/no Yes ET 200X
––– ––– Module diagnosis Yes/no Yes ET 200X
––– ––– Module status Yes/no Yes ET 200X
––– ––– Channel-specific
diagnosis
Yes/no Yes ET 200X
1
As of basic module 6ES7 143-1BF00-0XB0, version 5
2
The length of the diagnostic frame is 32 bytes.