EasyManua.ls Logo

Siemens SINAMICS G130 - Page 287

Siemens SINAMICS G130
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6.10 Communication via EtherNet/IP
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
287
Object class
Object name
Objects re-
quired
SINAMICS
objects
hex
dec
401 hex
1025
Parameter object
-
x
402 hex ...
43E hex
1026 ... 1086 Parameter object - x
1)
These objects are part of the Ethernet/IP system management.
For Assembly Object "4 hex" you define the data length. Assembly Object is assigned a
cycle in the control system.
Identity Object, Instance Number: 1 hex
Supported services
Class
Get Attribute all
Get Attribute single
Instance
Get Attribute all
Get Attribute single
Reset
Table 6- 30 Class Attribute
No.
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table 6- 31 Instance Attribute
No.
Service
Type
Name
Value/explanation
1 get UINT16 Vendor ID 1251
2 get UINT16 Device Type
- Siemens Drive
0C hex
3 get UINT16 Product code r0964[1]
4
get
UINT16
Revision
5
get
UINT16
Status
See the following table
6 get UINT32 Serial number bits 019: consecutive number;
bits 2023: Production identifier
bits 2427: Month of manufacture (0 = Jan, B =
Dec)
Bits 2831: Year of manufacture (0 = 2002)
7 get Short
String
Product name Max. length 32 bytes

Table of Contents

Other manuals for Siemens SINAMICS G130