Operating Modes, Program Operation (K1)
10.3 Processing a part program
Turning, Milling, Nibbling
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
181
Table 10- 10 Sequence with Powerup
Seque
nce
Command Boundary conditions
(must be satisfied before the
command)
Comments
1 Reset after power up
2 MD20110 RESET_MODE_MASK,
MD20150 GCODE_RESET_VALUES,
MD20152 GCODE_RESET_MODE
Control activated
after ramp up:
Reset sequence with evaluation
3 /_N_CMA_DIR/_N_PROG_EVENT_SPF or
name from MD11620
as an ASUB Implied call of the path name as
an ASUB
4 MD20110 RESET_MODE_MASK,
MD20150 GCODE_RESET_VALUES,
MD20152 GCODE_RESET_MODE
Control activated:
Reset sequence with evaluation
The G code reset position
continues to be specified with
machine data
Chronological sequences
For part program start and part program end:
Time sequence of VDI signals VB3300 0003 ("Program status" and "Channel status") when
processing a part program with an event-driven program call for part program start and part
program end:
(V3300 0003.7)
(V3300 0003.6)
(V3300 0003.5)
(V3300 0003.4)
(V3300 0003.2)
(V3300 0003.0)
Channel status
Reset
Interrupted
Active
Program status
End
EVENT_SPF
_N_PROG_
End
EVENT_SPF
_N_PROG_
Aborted
Active
EVENT_SPF
_N_PROG_
End
program
Part
Start
program
Part
Stopped
Running
Figure 10-1 Time sequence of the interface signals for program status and channel status (1)