6.10 Linear motors (1FN1 and 1FN3 motors)
6-130
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
3. Measuring system
Is an incremental or an absolute (EnDat) measuring system installed?
a) Incremental measuring system:
– Grid size _ _ _ _ _ _ mm
– Number of zero markers _ _ _ _ _ _
b) Absolute measuring system:
– Grid size _ _ _ _ _ _ mm
Determine the positive drive direction:
Which is the positive counting direction of the measuring system? (see
subsection 6.10.6)
––> Invert actual velocity value? j yes j no
4. Wiring
– Power section (connection with phase sequence UVW, clockwise
rotation)
– PE conductor connected?
– Shield attached?
– Various methods of temperature sensor evaluation
a) Evaluation by KTY84 via SIMODRIVE 611Donly
b) Evaluation via SIMODRIVE 611D and external
c) External evaluation only
Note:
In case a) a temperature sensor coupling lead (dongle) must be connec-
ted between –X411 and the measuring system.
Reference material: /PJLM/CON/ General notes on connections:
“Encoder connection” section
5. Measuring system cable
Check whether the measuring system cable is correctly attached to con-
nector X411 or to the adapter on the temperature sensor coupling lead.
See also:
Reference material: /PJLM/CON/ General notes on connections:
“Encoder connection” section