11
03/2006
11.13 Machine/setting data
11-263
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Machine data for non-activated channels is ignored and does not cause the
reading of an archive to be canceled.
Channels are activated by the settings in machine data
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP.
Channel machine data for channels for which a BAG=0 is assigned are ignored
when read.
The alarm generation options via MD 11220: INI_FILE_MODE also apply here.
Errors only relate to the data errors that are read in for channels to be down-
loaded.
Application:
Standard system start-up for various machines via a standardized archive file
that was created for the largest machine of a class of machines. For the smaller
machines, only the
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP is set so that only those
channels that can be processed by smaller machines are activated.
Changing the archive file:
The SinuCom ARC program can be used to change the archive file in
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP.This program is part of the
SinuCom NC start-up software which is described in
Reference material: /INC/ Start-up Tool SINUMERIK SinuCOM NC.
ALARM:
If machine data that should be ignored is identified when the archive is read in,
warning alarm 15025: “Channel %1 block %2 CHANDATA: Channel is not ac-
tive. %3 data will be ignored” is output.
11.13 Machine/setting data
The machine/setting data is listed in
Reference material: /LIS/ Lists
Upgrade from soft-
ware version 6.4
11 Data Back-U