EasyManua.ls Logo

Siemens SINUMERIK 840D Simodrive 611 digital - Machine;Setting Data

Siemens SINUMERIK 840D Simodrive  611 digital
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
03/2006
11.13 Machine/setting data
11-263
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Machine data for non-activated channels is ignored and does not cause the
reading of an archive to be canceled.
Channels are activated by the settings in machine data
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP.
Channel machine data for channels for which a BAG=0 is assigned are ignored
when read.
The alarm generation options via MD 11220: INI_FILE_MODE also apply here.
Errors only relate to the data errors that are read in for channels to be down-
loaded.
Application:
Standard system start-up for various machines via a standardized archive file
that was created for the largest machine of a class of machines. For the smaller
machines, only the
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP is set so that only those
channels that can be processed by smaller machines are activated.
Changing the archive file:
The SinuCom ARC program can be used to change the archive file in
MD 10010: ASSIGN_CHAN_TO_MODE_GROUP.This program is part of the
SinuCom NC start-up software which is described in
Reference material: /INC/ Start-up Tool SINUMERIK SinuCOM NC.
ALARM:
If machine data that should be ignored is identified when the archive is read in,
warning alarm 15025: “Channel %1 block %2 CHANDATA: Channel is not ac-
tive. %3 data will be ignored” is output.
11.13 Machine/setting data
The machine/setting data is listed in
Reference material: /LIS/ Lists
Upgrade from soft-
ware version 6.4
11 Data Back-U
p

Table of Contents

Related product manuals