Position the cursor on the Initialization program (INI) directory. Press the “V24”
soft key. The initialization program “%_N_INITIAL_INI” is output with the follow-
ing data:
S Global user data
S Option data
S Protection areas
S R parameters
S Setting data
S Machine data
S Tool/magazine data
S Zero offsets
No
Compensation data (EEC, QEC, CEC)
Part programs
Definition data and macros
Part programs, workpieces, cycles
PLC programs and data
Display machine data, drive machine data
If you place the cursor on “NC active data” and start outputting the data “via
V24”, an initialization program called %_N_INITIAL_INI is also output, although
this contains all the data in the “NC active data” directory, i.e. with compen-
sations.
11.7.3 Outputting the PLC data via V24
The PLC data must first be saved as an archive file before it can be output via
the V24 interface.
Outputting the
initialization
program (INI)
PLC data
11 Data Back-U
p

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D Simodrive 611 digital and is the answer not in the manual?

Siemens SINUMERIK 840D Simodrive 611 digital Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840D Simodrive 611 digital
CategoryControl Unit
LanguageEnglish

Related product manuals