11
03/2006
11.7 Data output
11-242
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Position the cursor on the Initialization program (INI) directory. Press the “V24”
soft key. The initialization program “%_N_INITIAL_INI” is output with the follow-
ing data:
S Global user data
S Option data
S Protection areas
S R parameters
S Setting data
S Machine data
S Tool/magazine data
S Zero offsets
No
– Compensation data (EEC, QEC, CEC)
– Part programs
– Definition data and macros
– Part programs, workpieces, cycles
– PLC programs and data
– Display machine data, drive machine data
If you place the cursor on “NC active data” and start outputting the data “via
V24”, an initialization program called %_N_INITIAL_INI is also output, although
this contains all the data in the “NC active data” directory, i.e. with compen-
sations.
11.7.3 Outputting the PLC data via V24
The PLC data must first be saved as an archive file before it can be output via
the V24 interface.
Outputting the
initialization
program (INI)
PLC data
11 Data Back-U