Power-On and Power-Up
5.1 Start-up order
The mechanical and electrical assembly work on the plant must be complete.
Before you commence starting up the control, you must ensure that it powers
up correctly with all its components and that it has been installed in compliance
with the EMC Guidelines.
The start-up procedure is detailed below. The order in which the individual steps
are taken is not mandatory, but recommended:
1. Power up and check the SINUMERIK 840D (chapter 5)
2. Basic settings (subsection 6.6.1) and
Entering the memory configuration (section 6.7)
3. Scaling machine data (section 6.8)
4. Setting the axis configuration (subsection 6.9.1)
5. Configuration and parameter settings for the drives (subsection 6.9.2)
6. Setting axis and spindle-specific machine data
Axis speeds (subsection 6.9.9)
Axis monitoring devices (subsection 6.9.11)
Axis reference point approaches (subsection 6.9.12)
Spindle data (subsection 6.9.13)
Sensor matching for spindle (subsection 6.9.15)
Spindle speeds (subsection 6.9.16)
Positioning the spindle (subsection 6.9.17)
Spindle monitoring devices (subsection 6.9.19)
7. Transferring PLC user program and alarm texts (chapter 7/8)
8. Axis and spindle test run (chapter 9)
9. Drive optimization (chapter 10)
Frequency response measurements for speed and position control loops
(section 10.5)
Analog output (section 10.8)
10. Data back-up (chapter 11)
11. Replacing hardware and software (chapter 12)
Start-up sequence
5

Table of Contents