3.8 PCU 20/50/50.3/70
3.8.1 Settings with HMI Embedded/HMI Advanced for
SINUMERIK 840D
The operating panel interface (BTSS) is the default setting (1.5 MBaud).
S PCU 20 with HMI Embedded
HMI Embedded automatically adjusts to the baud rate.
S PCU 50/50.3/70 with HMI Advanced
The HMI Advanced must be set to a baud rate of 1.5 MBaud in the “Start-up/
HMI/Operating panel” menu.
The display machine data (BTSS settings) are set via the user interface of the
HMI in the Start-up area “Start-up” –> “Machine data”.
S PCU 20 with HMI Embedded
The HMI Embedded software is available in six languages by default
(English, German, French, Italian, Spanish and simplified Chinese).
S PCU 50/50.3/70 with HMI Advanced
HMI Advanced is always supplied as a multilingual version. The default
setting is English.
MD 9006 (for HMI Embedded):
This MD is used to enter the time after which the screen saver mode is activa-
ted if no key is pressed on the operating panel within the specified time.
A detailed description of the functions and parameter settings can be found in
the following documentation:
Reference material: /IAM/ Start-up Guide, IM2, HMI Embedded
IM4, HMI Advanced
BTSS (standard)
Setting the display
machine data
Language
Screen saver mode