SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Definition file for the machine manufacturer
%_N_MACCESS_DEF File for machine manufacturer
;$PATH=/_N_DEF_DIR
; Write protection for file is set to value 1 for machine manufacturer.
N010 ; Predefined procedures:
N020 REDEF CONTPRON APX 1 ; Record preparation for cutting cycle,
; Protection level: Machine manufacturer
N030 REDEF GEOAX APX 3 ; Geo axis assignment,
; Protection level: End user
N110 ; Predefined functions:
N120 REDEF INTERSEC APX 1 ; Point of intersection calculation
; Protection level: Machine manufacturer
; Write access to
N110 ; System variables:
N120 REDEF $P_CHBFR APW 3 ; Write basic frame
N130 REDEF $TC_MAP1 APW 3 ; Magazine data for tool management
; Write protection level: End user
N210
; Synchronous actions
N220 REDEF DO APX 2
; Protection level: Start-up engineer, Service
; Machine data
; $MC_GCODE_RESET_VALUES for
N310 ; Protection level: Enable key switch 0
N320 REDEF $MC_GCODE_RESET_VALUES APR 7 APW 7
M17
Definition file for the end user
%_N_UACCESS_DEF File for end user
;$PATH=/_N_DEF_DIR
; Write protection for file is set to value 3 for end user.
; Protection level for writing
; $MC_GCODE_RESET_VALUES for
; set end user
N510 REDEF $MC_GCODE_RESET_VALUES APR 7 APW 3
M17