6 Pro
rammin
the control
6
03/2006
6.4 Display filter for machine data
6-63
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
S “Deselect all” soft key
The checkboxes for the groups are set to inactive.
The soft key does not affect the following checkboxes:
– Filter active
– Expert mode
– Index from to
– All others
S “Cancel” soft key
– Returns to the machine data screen.
– The former filter settings remain valid
– Any changes are discarded
S “OK” soft key
– Modified filter settings are saved.
– The machine data screen is refreshed
– The input field is positioned on the current MD again.
If the MD was hidden, then it is positioned on the first MD.
The “Expert mode” setting is intended to simplify and give a clearer overview of
the initial start-up process.
Procedure:
S Activate all filters (check)
S Activate display filters (check)
S Disable expert mode (do not check)
S Only the machine data required for the basic functions are displayed
(e.g. proportional gain, reset time, filters).
Machine data for adaptation, the reference model, etc, is not displayed.
If the filter setting hides all the machine data in an area, when this area is selec-
ted, the following message appears:
“Unable to display machine data with the current access rights and the current
filter setting”.
Press the “OK” soft key to acknowledge and blank machine data screen
appears.
Expert mode
Hide all machine
data