Appendix
B-42
3690 Distance Pickup L31E (Dis.Pickup
L31E)
Distance protec-
tion, general set-
tings
OUT * ON LED BO 28 90 2
3691 Distance Pickup L23 (Dis.Pickup
L23)
Distance protec-
tion, general set-
tings
OUT * ON LED BO 28 91 2
3692 Distance Pickup L23E (Dis.Pickup
L23E)
Distance protec-
tion, general set-
tings
OUT * ON LED BO 28 92 2
3693 Distance Pickup L123 (Dis.Pickup
L123)
Distance protec-
tion, general set-
tings
OUT * ON LED BO 28 93 2
3694 Distance Pickup123E
(Dis.Pickup123E)
Distance protec-
tion, general set-
tings
OUT * ON LED BO 28 94 2
3695 Dist.: Phi phase L1 Pickup (Dis
Pikkup ϕ L1)
Distance protec-
tion, general set-
tings
OUT * * M LED BO
3696 Dist.: Phi phase L2 Pickup (Dis
Pikkup ϕ L2)
Distance protec-
tion, general set-
tings
OUT * * M LED BO
3697 Dist.: Phi phase L3 Pickup (Dis
Pikkup ϕ L3)
Distance protec-
tion, general set-
tings
OUT * * M LED BO
3701 Distance Loop L1E selected forward
(Dis.Loop L1-E f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3702 Distance Loop L2E selected forward
(Dis.Loop L2-E f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3703 Distance Loop L3E selected forward
(Dis.Loop L3-E f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3704 Distance Loop L12 selected forward
(Dis.Loop L1-2 f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3705 Distance Loop L23 selected forward
(Dis.Loop L2-3 f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3706 Distance Loop L31 selected forward
(Dis.Loop L3-1 f)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3707 Distance Loop L1E selected reverse
(Dis.Loop L1-E r)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3708 Distance Loop L2E selected reverse
(Dis.Loop L2-E r)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
3709 Distance Loop L3E selected reverse
(Dis.Loop L3-E r)
Distance protec-
tion, general set-
tings
OUT * ON
OFF
LED BO
F.No. Description Function Type of
Information
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information-No
Data Unit (ASDU)
General Interrogation