Cabinet Modules
5.6 Motor Modules in chassis format
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
227
5.6.4
Technical specifications
Table 5- 36 Technical specifications for Motor Modules in chassis format, line voltage 380 to 480 V 3 ph. AC, DC-link
voltage 510 to 720 V DC, part I
Order no.
6SL3720-
1TE32-
1AU3
1TE32-
6AU3
1TE33-
1AU3
1TE33-
8AU3
1TE35-
0AU3
1TE36-
1AU3
Unit rating
- for I
L
(50 Hz 400 V)
1)
- for I
H
(50 Hz 400 V)
1)
- for I
L
(60 Hz 460 V)
2)
- for I
H
(60 Hz 460 V)
2)
kW
kW
HP
HP
110
90
150
150
132
110
200
200
160
132
250
200
200
160
300
250
250
200
400
350
315
250
500
350
Output current
- Rated current I
N A
- Base load current I
L
3)
- Base load current I
H
4)
- Maximum current I
max A
A
A
A
A
210
205
178
307
260
250
233
375
310
302
277
456
380
370
340
555
490
477
438
715
605
590
460
885
DC-link current
-
Rated current I
N DC
when supplied via:
- Basic/Smart Line Module
- Active Line Module
- Base load current I
L DC
3)
when supplied via:
- Basic/Smart Line Module
- Active Line Module
- Base load current I
H DC
4)
when supplied via:
- Basic/Smart Line Module
- Active Line Module
A
A
A
A
A
A
252
227
245
221
224
202
312
281
304
273
277
250
372
335
362
326
331
298
456
411
444
400
405
365
588
529
573
515
523
470
726
653
707
636
646
581
Supply voltages
- DC-link voltage
- Electronic power supply
- Output voltage
V
DC
V
DC
V
ACrms
510 to 720
24 (20.4 to 28.8)
0 to 0.72 x DC-link voltage
Current demand
- Auxiliary supply 24 V DC
- 400 V AC
A
A
0.8
0.63
0.8
1.13
0.9
1.8
0.9
1.8
0.9
1.8
1.0
3.6
DC-link capacitance
µF
4200
5200
6300
7800
9600
12600
Pulse frequency
- Rated frequency
- Pulse frequency, max.
- without current derating
- with current derating
kHz
kHz
kHz
2
2
8
2
2
8
2
2
8
2
2
8
2
2
8
1.25
1.25
7.5
Power loss, max.
5)
- at 50 Hz 400 V
- at 60 Hz 460 V
kW
kW
1.86
1.94
2.5
2.65
2.96
3.1
3.67
3.8
4.28
4.5
5.84
6.3
Cooling air requirement
cfm
m
3
/s
360
0.17
487
0.23
763
0.36
763
0.36
763
0.36
1653
0.78
Sound pressure level L
pA
(1 m) at 50/60 Hz
dB(A)
67
69
69
69
69
72
Motor connection U2, V2, W2
- Screws
- Max. conductor cross-section (IEC)
- Max. conductor cross-section (NEC, CEC)
mm
2
AWG/MCM
2/M12
2 x 185
2 x 350
2/M12
2 x 185
2 x 350
2/M12
2 x 240
2 x 500
2/M12
2 x 240
2 x 500
2/M12
2 x 240
2 x 500
2/M12
4 x 240
4 x 500

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals