falling-thresholdvalue - A number at
which the alarm is reset. This value
ranges between 0 and 2147483647.
NOTE: Falling threshold must be less
than rising threshold.
rising-event-number - The event
number to trigger when the rising
threshold exceeds its limit. This value
ranges between 1 and 65535.
falling-event-number - The event
number to trigger when the falling
threshold exceeds its limit. This value
ranges between 1 and 65535.
OwnerOwner of the alarm, string of
length 127.
Step 3
rmon event <number (1-65535)> [description
<event-description (127)>] [log] [owner
<ownername (127)>] [trap <community (127)>]
(Optional) Add an event in the RMON
event table that is associated with an
RMON event number.
Number - Event number
Description - Description of the event
Log - Used to generate a log entry
Owner - Owner of the event, , in range
1- 127 characters
Trap - Used to generate a trap. The
SNMP community string is to be passed
for the specifiedtrap.
NOTE : When RMON event trap is
enabled, SNMP agent must be
configured prior to configuring the
RMON alarm function as described
in SNMP Configuration guide
(www.supermicro.com).
Step 4
end
Exit from Configuration mode.
Step 5
show rmon [statistics [<stats-index (1-65535)>]]
[alarms] [events] [history [history-index (1-65535)]
[overview]]
Display RMON statistics, alarms, events
history and overview.