Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
38
To configure multiple interfaces, use
the “interface range …” command. To
provide a range use a hyphen (-)
between the start and end interface
numbers. E.g.: int range fx 0/1-10
To provide multiple interfaces or
ranges, separate with a comma (,).
E.g.: int range fx 0/1-10, fx 0/20
If multiple interfaces are provided, the
next step will perform the particular
configuration on all these interfaces.
Fec-mode
Enable FEC mode on interface.
End
Exits the configuration mode.
show interface
Displays the fec mode for the interface.
write startup-config
Optional step saves this configuration
to be part of startup configuration.
The example below shows the commands used to configure the interface description.
SMIS# configure terminal
SMIS(config)# interface Fx 0/22
SMIS(config-if)# fec-mode
SMIS(config-if)# end
SMIS
SMIS# sh int Fx 0/22
2.4 Time Management
The system time and date on Supermicro switches can be managed by Network Time Protocol (NTP) or
configured manually.
NTP provides synchronization of network resources by a synchronized network timestamp. Supermicro
switches can function as an NTP client over UDP and receive the time from an NTP server in the network.
The time
Parameter
Default Value
Timezone offset
None
NTP status
Disabled
NTP operation
Unicast
NTP authentication
None
NTP server
None
NTP Broadcast mode
No

Table of Contents