Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
SMIS# configure terminal
SMIS(config)# interface Fx 0/21
SMIS(config-if)# no snmp trap link-status
SMIS(config-if)# end
SMIS# show interface Fx 0/21
Fx0/21 up, line protocol is up (connected)
Bridge Port Type: Customer Bridge Port
Hardware Address is 00:30:48:e3:04:89
MTU 1500 bytes, Full duplex, 1 Gbps, Auto-Negotiation
HOL Block Prevention enabled.
Input flow-control is off,output flow-control is off
Link Up/Down Trap is disabled
Reception Counters
Octets : 753
Unicast Packets : 0
Broadcast Packets : 0
Multicast Packets : 9
Pause Frames : 0
Undersize Frames : 0
Oversize Frames : 0
CRC Error Frames : 0
Discarded Packets : 0
Error Packets : 0
Unknown Protocol : 0
Transmission Counters
Octets : 9043
Unicast Packets : 0
Non-Unicast Packets : 74
Pause Frames : 0
Discarded Packets : 0
Error Packets : 0
11.8 Sub-Agent
Supermicro switches can act as a Sub-Agent to another SNMP agent. SNMP Agent and Sub-Agent
communication is via a protocol called AgentX. The Sub-Agent feature is disabled by default.
Follow the steps below to configure an SNMP Sub-Agent.
Enters the configuration mode
enable snmpsubagent{master { ip4
<ipv4_address> | ip6 <ipv6_address> } [port
Configures the switch as SNMP Sub-
Agent.