The example below shows the commands used to configure the Syslog facility.
SMIS# configure terminal
SMIS(config)#logging facility local5
SMIS(config)# end
SMIS# show logging
System Log Information
----------------------
Syslog logging: enabled(Number of messages 0)
Console logging: disabled(Number of messages 0)
File logging: disabled(Number of messages 0)
Log File Name:
File Max Entries: 500
TimeStamp option: enabled
Trap logging: Critical
Log server IP: None
Facility: local5
Buffered size: 50 Entries
LogBuffer: (0 Entries)
LogFile: (0 Entries)
2.6.7 Traps
Supermicro switches provide an option for specifying the type of traps that are to be logged.
Follow the steps below to configure logging traps.
Command
Description
configure terminal
Enters the configuration mode
logging trap [{ <level (0-7)> | alerts | critical |
debugging | emergencies |errors |informational |
notification | warnings }]
Configure Logging Traps.
There are various levels of traps that
can be logged.
Level 0 Emergencies
Used for logging messages that are
equivalent to a panic condition.
Level 1 Alerts
Used for logging messages that require
immediate attention.
Level 2 Critical
Used for logging critical errors.
Level 3 Errors
Used for error messages.

Table of Contents