Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
41
Key-numberkey number in the range
1-65535, used for MD5.
Key-textNTP key text to be used along
with key-number for MD5.
End
Exits the configuration mode.
show ntp
Displays the NTP configuration.
write startup-config
Optional step saves this configuration
to be part of startup configuration.
The “no ntp key” command deletes the NTP authentication key.
The example below shows the commands used to configure NTP.
SMIS(config)# ntp key 200 For-server1
SMIS(config)# show ntp
[NTP] ntp is enabled
Server Key Prefer
=============== ===== ======
Key # Key
======= ====================================
200 For-server1
Time zone offset not set
2.4.4 NTP Broadcast
NTP server messages can be broadcast or unicast. By default, Supermicro switches receive unicast NTP
messages.
Follow the below steps to configure Supermicro switches to receive NTP broadcast messages from the NTP
server.
Command
Description
configure terminal
Enters the configuration mode
ntp broadcast [authentication]
Configure NTP broadcast.
authentication If specified, NTP
authentication is enabled for broadcast
mode.
End
Exits the configuration mode.