12-8 COOLING SYSTEM
1 Washer
2 Water pump shaft
3 Water pump driven gear
4 Water pump case
5 Bearing
6 Oil seal
7 Impeller
8 Washer
Install the dowel pins 1 and a new gasket 2.
.
Tighten the crankcase cover bolts to the specified torque.
Crankcase cover bolt: 11 N·m (1.1 kgf-m, 8.0 lb-ft)
After reinstalling the water pump, check the followings.
Kick starter lever (8-6)
Brake pedal (2-20, 5-9)
Transmission oil level (2-9)
Engine coolant level (2-11)
CAUTION
Use a new gasket to prevent engine coolant leakage.
Apply THREAD LOCK SUPER or equivalent thread lock