ELECTRICAL SYSTEM 13-9
STATOR COIL
• Remove the seat and fuel tank. (5-4)
• Disconnect the magnet lead wire coupler 1.
Measure the stator coils electrical resistance with the multi-cir-
cuit tester.
Reference data [at 20 °C (68 °F)]
NOTE:
The resistance of stator varies depending on the temparatare
(stator and atmosphere).
Tester knob indication: Resistance (Ω)
09900-25008: Multi-circuit tester
Exciter Black/Red – Red/White 24 – 40 Ω
Pick-up Red – Green 72 – 127 Ω
Charge Yellow – Black/White 1.6 – 2.6 Ω
R/W
G
R
B/R
Y
B/W