e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 186
(13) Pull out the heat pipe roller [1] by sliding it
inside of the fuser belt and pushing it to the
outside so that it will not contact with the
fuser roller.
Notes:
• Be careful not to damage the fuser roller
since its surface is soft and easily
scratched, especially rubbing the surface
could cause a crack. If it is damaged,
replace it with a new one.
• Install the heat pipe roller [1], letting the
side with a rotor be on the front side.
Fig. 4-538
Fig. 4-539
(14) Remove front E-ring, and take off bearing [1],
roller [2] and bushing [3].
(15) Remove rear E-ring. Take off bushing [3] and
bearing [1].
Fig. 4-540
Notes:
• When storing the heat pipe roller, place it
in a horizontal position.
• When discarding the heat pipe roller,
discard after opening a hole from the axial
edge of the D-cut side [1].
Fig. 4-541
[
1
]
[
2
]
[
3
]
[
1
]
[
3
]