432MAINTENANCEANDLUBRICATION
Repositionorshieldanypartsthatwouldbedamagedbyhightemperaturesduring
welding.
W8003200
Completethebatterycableremovalbyremovingthepositivecablelast.
•Attachtheweldergroundcableasclosetotheweldareaaspossible(6inches
orlessfromtheplacebeingwelded).
•DONOTconnecttheweldergroundcablenearanyelectronicmodule,suchas
theEECUoritscoolingplate.
•Weldingcablesshouldnotbeallowedtolieon,orrunparallelwithanywiring.
•Weldingcablesshouldnotbeallowedtolienearanyelectroniccomponentduring
welding.
•Afterweldingiscompleteandtheweldedareashavecooled,inspectwiringand
componentsforpossibleshorts,nicks,abrasionorotherdamage.