Service Manual FB 7100 Programming
4 - 76 January, 2005
4.3.9 Multibrew settings menu
Introduction The Multibrew settings menu is used to set parameters for the multibrew
function.
This table describes the options of the Multibrew settings menu.
v Sel Esc^
MULTIBREW SETTINGS
* Preset value
Min value
Sub menu Description
Preset value The function is used to define a preset number of
portions between 0 and 20 to be dispensed when
the multibrew function is activated.
Example: A setting of 6 results in an automatic
dispensing of six portions when the multibrew
function is activated provided that this number is
not changed by the user prior to activating.)
Min value A number can be set to define a minimum of
portions to be dispensed during a multibrew vend.
The minimum possible number of portions is 1.
Max value A number can be set to define a maximum of
portions to be dispensed during a multibrew vend.
The maximum possible number of portions is 20.
Means of action This function is used to define how multibrew
vends should be activated. The options are:
Off: Multibrew is not possible
Key: Multibrew is activated by a key.
But: Multibrew is activated by pressing the
Multibrew button.
(See also section Key discount and Multibrew
settings, on page 4-77.)
MB Discount The discount option makes it possible to set a
discount rate which is given on multibrew vends.
Example: A setting of 20 results in a discount of
20% when the multibrew function is activated.
A setting of 100 means free vend.