EasyManua.ls Logo

Wittenborg FB 7100 - Removing the Water Level Sensor (Electrode)

Wittenborg FB 7100
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual FB 7100 Water System
January, 2005 5A - 9
Illustration The overboil thermostat is located at the front of the boiler as illustrated
below:
Installation Installation is done in reverse order.
A.2.9 Removing the water level sensor (electrode)
Preparation Before removing the water level sensor
Open the door.
Switch off the main switch.
Remove coffee waste bucket and pull forward the base tray.
Release distributor head and rest it on top of its mounting arm, see this
section, page 5A-2.
Remove cover for water system, see this section, page 5A-2.
Removal Follow these steps to remove the water level sensor:
Installation Installation is done in reverse order. Apply water on reinstallation.
Step Action Illustration
1 Pull off the electrical connection.
2 Pull the water level sensor out of its
holder.