EasyManua.ls Logo

Wittenborg FB 7100 - Replacing the Microswitch BSSW

Wittenborg FB 7100
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual FB 7100 Brewer System
5B - 24 January, 2005
B.3.14 Replacing the microswitch BSSW
Definition BSSW is an abbreviation of brewer safety switch.
Preparation Before replacing the brewer safety switch:
Switch off the main switch, disconnect the power supply, and close the
water tap.
Remove the brewer, see this section, page 5B-4.
Remove the brewer cylinder, the filter plate holder and the scraper, see
this section, page 5B-7.
Remove the brewer housing, see this section, page 5B-8.
Disassembling the scraper arms, see this section, page 5B-13.
Replacement Follow these steps to replace the brewer safety switch:
Horizontally place the microswitch into the 3 mm holes in the highest po-
sition possible.
Step Action Illustration
1 Remove the fastening screws
(1) with washers (2) and nuts
(4) to replace microswitch (3)
with new switch.
2 Unplug the cable lugs from the
defective microswitch, and
connect them to the new
microswitch on the outer
contact pins (5).
Make sure that the
insulation hose is
positioned correctly.
3 Fasten the new microswitch as
illustrated on drawing.
Observe that the
screws are not
fastened too tight.
4 Check the function of the microswitch.
1
2
4
5
3

Table of Contents

Other manuals for Wittenborg FB 7100

Related product manuals