Service Manual FB 7100 Water System
January, 2005 5A - 13
Disassembly Follow these steps to disassemble the inlet valve and connecting hose:
Assembly Assembly is done in reverse order.
A.2.14 Resetting the pressure security valve of the inlet valve
Preparation Before removing the inlet valve
Open the door.
Switch off the main switch.
Remove coffee waste bucket and pull forward the base tray.
Release distributor head and rest it on top of its holder arm, see this
section, page 5A-2.
Remove cover for water system, see this section, page 5A-2.
Resetting Follow these steps to reset the overflow thermostat
Step Action Illustration
1 Disconnect the electrical plug
connections of the inlet valve.
2 Remove hoses from the inlet
valve.
1) Connecting hose
2) Hose from overflow
3) Hose from bottom of boiler
3 Loosen screw of holder for inlet
valve slide upward and lift out.
4 Loosen and remove two screws
to remove inlet valve.
Step Action Illustration
1 Disconnect hose at pressure
security valve(1).
2 Empty water from the hose into
waste bucket.
3 Unscrew hose connection to
connecting hose to release the
pressure in inlet valve (2).
1
2