Service Manual FB 7100 Brewer System
January, 2005 5B - 5
Removal Follow these steps to remove the brewer unit
Installation Installation is done in reverse order.
Step Action
1 If necessary, remove the filter plate, the scraper, and the brewer
cylinder.
2 Unscrew 2 screws and lift out brewer.
Warning! If brewer cylinder is not closed, lift out brewer by the sides. Do
not touch underneath the unit!
3 Disconnect the 15-pole plug of the harness at the back of the brewer.
4 If necessary, assemble the filter plate, the scraper, and the brewer
cylinder.