Service Manual FB 7100
2 - 10 January, 2005
2.4 Installation requirements and safety notes
Prerequisite for
installation
Before starting the installation:
Check for adequate space for correct ventilation.
A distance of 120 mm is required from the rear side of the machine to
the wall.
Check for clear space of 470 mm in front of the machine to allow the
door to be fully opened.
Ensure that the supply voltage corresponds to the voltage indicated on
the rating plate which is located on the rear wall of the machine.
Check the connections and make sure that the national voltages and
tolerances are provided.
The machine must be earthed.
Ensure that the fuse of the group to which the machine is connected is
in accordance with the national regulations.
If required, ask for detailed information on voltage and tolerance
values at the local energy supply companies.
Safety notes on
installation
Attention:
The machine is suitable for indoor use only.
Warnings:
Check drinking water quality.
The machine must be connected to the mains in accordance with all
official regulations and local regulations laid down by the electricity
and water companies. Observe the local regulations.
Ensure that the supply voltage corresponds to the voltage indicated on
the rating plate which is located on the rear wall of the machine.
The machine must be connected to an earthed electric circuit which is
secured by an extra fuse.
Rinse the machine before putting it into operation.