Service Manual FB 7100
2 - 10 January, 2005
2.4 Installation requirements and safety notes
Prerequisite for
installation
Before starting the installation:
• Check for adequate space for correct ventilation.
A distance of 120 mm is required from the rear side of the machine to
the wall.
• Check for clear space of 470 mm in front of the machine to allow the
door to be fully opened.
• Ensure that the supply voltage corresponds to the voltage indicated on
the rating plate which is located on the rear wall of the machine.
• Check the connections and make sure that the national voltages and
tolerances are provided.
The machine must be earthed.
• Ensure that the fuse of the group to which the machine is connected is
in accordance with the national regulations.
• If required, ask for detailed information on voltage and tolerance
values at the local energy supply companies.
Safety notes on
installation
Attention:
• The machine is suitable for indoor use only.
Warnings:
• Check drinking water quality.
• The machine must be connected to the mains in accordance with all
official regulations and local regulations laid down by the electricity
and water companies. Observe the local regulations.
• Ensure that the supply voltage corresponds to the voltage indicated on
the rating plate which is located on the rear wall of the machine.
• The machine must be connected to an earthed electric circuit which is
secured by an extra fuse.
• Rinse the machine before putting it into operation.