3. Adjust the position of the Sensor such that:
the Actuator of the Sensor still extends above the bottom surface of
the Document Hold Down Guide when the Sensor electrically goes
from the deactuated to the actuated state
the Actuator operates freely with the Document Hold Down Guide
installed
the end of the Actuator is below the surface of the Platen in the
deactuated state.
4. Tighten the two Retaining Screws.
5. Check that the operation of the Sensor is still within the specification.
6. Install the Rear Cover (REP 4.1.2).
7. Close the Top Cover.
8. Perform ADJ 4.1.2 - Calibrate Document Registration.
4/97
ADJ 4.1.7 4-46 7356 SCANNER