...REP 4.1.6 Edge Present Sensor
Parts List on PL 5.1
Removal
WARNING
Switch off the Scanner and disconnect the Power
Cord.
1. Remove the Right Side Panel (REP 4.1.1).
2. Remove the Rear Panel (REP 4.1.2).
3. (Figure 1): Prepare to remove the Edge Present Sensor.
NOTE: The string attached in step 3b is used later to pull the cable
back through the channel when the sensor is reinstalled.
Channel
Attach a string at
least 30 in (76
cm) long to the
connector and
cable
4. (Figure 2): Detach the Retaining Plate.
String
01030A-COB
A
Disconnect
Connector Pl
from the Control
PWB
01028A-COB
A
Remove the 2
screws, and
lower the
Retaining Plate
Figure 2. Removing the Edge Present Sensor
Figure 1. Disconnecting Connector P1
7356 SCANNER
4/97
4-9
REP 4.1.6