Specifications
14.1.1 Standard Drive Series
14 -4
Table 14.2 Standard 400 V Series
Model UAAS FZ***E
A-06 A-08 A-11 A-15 A-19 A-22 J-30 J-37 J-45
Rated
Output
*
1
30-minute Rating (S2)
50%ED Rating (S3)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
50
(37)
60
(45)
HP
(kW)
Continuous Rating
(S1)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
50
(37)
Rated
Base Speed 1500 1150
spee
(min
−1
)
Maximum Speed 8000 6000 4500
Out
ut Tor
ue at Base
N·m 23.5 35.0 47.7 70.0 95.0 117.6 182.3 249.0 306.8
Motor
Speed Continuous Rat-
ing
lb·ft
(kgf·m)
17.4
(2.40)
25.8
(3.57)
35.8
(4.87)
51.7
(7.14)
70.6
(9.74)
86.9
(12.0)
134
(18.6)
183.7
(25.4)
226.4
(31.3)
Rotor Inertia J (GD
2
/4) lb·ft
2
(kg·m
2
)
0.411
(0.0173)
0.617
(0.026)
0.759
(0.032)
1.614
(0.068)
1.970
(0.083)
2.326
(0.098)
6.122
(0.258)
8.068
(0.340)
11.22
(0.473)
Overload Capacity
120%, 60s of 30-minute rating
Vibration (µ·m)
V5 V10
Noise Level 75dB (A) or less
80dB (A) or less
Ambient Temperature, Humidity
0°Cto40°C (32°F to 104°F), 95% or less (non-condensing)
Approx. Mass lb
(kg)
119
(54)
130
(59)
150
(68)
207
(94)
238
(108)
269
(122)
481
(218)
580
(263)
783
(355)
Model CIMR-M5j
*
2
45P5 47P5 4011 4015 4018 4022 4030 4037 4045
Continuous Rated Input Current
(A)
8.8 13.1 17.9 26.2 35.7 44.1 52.4 71.4 88.2
Continuous Rated Output Current
(A)
10.4 15.5 20 28 40 49 56.5 80 98
Control Method Sine wave PWM Inverter (Vector control)
er
Speed Control Range 40 min
−1
to maximum motor speed
ert
Speed Regulation 0.2% maximum speed or less
In
Overload Capacity
*3
120%, 60s of 30-minute rating
Approx. Mass lb (kg) 11 (5) 27 (12) 35 (16)
Width 3.94 (100) 5.91 (150) 9.84 (250)
Dimensions in inches
*4
Height 13.78 (350)
mm
Depth 12.60 (320)
Model CIMR-MR5j
*
2
45P5 47P5 4011 4015 4018 4022 4030 4037 4045
Required Power Capacity (kVA) 9 12 19 24 30 36 48 60 70
Continuous Rated Input Current
(A)
6.7 9.85 13.4 19.7 26.8 33.1 39.3 53.6 66.2
roller
Continuous Rated Output Current
(A)
8.8 13.1 17.9 26.2 35.7 44.1 52.4 71.4 88.2
Cont
Power Supply
Three-phase, 400 VAC (50/60Hz); 440 VAC (50/60Hz); 460 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
nverter
*
5
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
Co
Control Method
Power regenerative control (120_ current conduction)
Overload Capacity 120% for one minute, 200% for one second
Approx. Mass lb (kg) 11 (5) 27 (12) 46 (21)
Width 3.94 (100) 5.91 (150) 9.84 (250)
Dimensions in inches
*4
Height 13.78 (350)
mm
Depth 12.60 (320)
Power Supply AC Reactor Code
No.
X002501 X010099 X010100 X010101 X010102 X010103 X010104 X010105 X010106
14