Table 5.5 Fault Displays
HOA
Keypad
Display
Name Page
bAT HOA Keypad Battery Voltage Low 207
bUS Option Communication Error 207
CE MEMOBUS/Modbus Communication Error 207
CoF Current Offset Fault 207
CPF00,
CPF01
<1>
Control Circuit Error 208
CPF02 A/D Conversion Error 208
CPF03 Control Board Connection Error 208
CPF06 EEPROM Memory Data Error 208
CPF07,
CPF08
Terminal Board Connection Error 208
CPF20,
CPF21
<2>
Control Circuit Error 208
CPF22 Hybrid IC Error 209
CPF23 Control Board Connection Error 209
CPF24 Drive Unit Signal Fault 209
CPF46 Terminal Board Error 209
EF0 Option Card External Fault 209
EF1 to EF7 External Fault (input terminal S1 to S7) 209
Err EEPROM Write Error 210
FAn Internal Fan Fault 209
Fn1 External Fan Fault 210
FbH Excessive PI Feedback 210
FbL PI Feedback Loss 211
GF Ground Fault 211
LF Output Phase Loss 211
LF2 Current Imbalance 211
nSE Node Setup Error 211
oC Overcurrent 212
oFA00 Option Card Connection Error (CN5) 213
HOA
Keypad
Display
Name Page
oFA01 Option Card Fault (CN5) 213
oFA05,
oFA06
Option Card Error (CN5) 213
oFA10,
oFA11
Option Card Error (CN5) 213
oFA12 to
oFA17
Option Card Connection Error (CN5) 213
oFA30 to
oFA43
Comm Option Card Connection Error (CN5) 213
oH Heatsink Overheat 213
oH1 Heatsink Overheat 213
oH3 Motor Overheat Alarm (PTC input) 213
oH4 Motor Overheat Fault (PTC input) 214
oL1 Motor Overload 214
oL2 Drive Overload 215
oL3 Overtorque Detection 1 215
oL7 High Slip Braking oL 215
oPr Operator Connection Fault 215
ov Overvoltage 216
ov2 Overvoltage 2 216
PF Input Phase Loss 216
SEr Too Many Speed Search Restarts 217
STo Pull-Out Detection 217
TdE Time Data Error 217
TIM Time Not Set 217
UL3 Undertorque Detection 1 218
UL6 Motor Underload 218
Uv1 DC Bus Undervoltage 218
Uv2 Control Power Supply Undervoltage 218
Uv3 Soft Charge Circuit Fault 219
voF Output Voltage Detection Fault 219