EasyManua.ls Logo

YASKAWA Z1000 - C6: Carrier Frequency

YASKAWA Z1000
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
u
C6: Carrier Frequency
No.
(Addr.
Hex)
Name LCD Display Description Values Page
C6-02
(224)
Carrier Frequency
Selection
CarrierFreq Sel
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
7: Swing PWM1
8: Swing PWM2
9: Swing PWM3
A: Swing PWM4
F: Program
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
7: Swing PWM1 (Audible sound 1)
8: Swing PWM2 (Audible sound 2)
9: Swing PWM3 (Audible sound 3)
A: Swing PWM4 (Audible sound 4)
B to E: No setting possible
F: User-defined (determined by C6-03 through C6-05)
Default:
<1>
Range: 1 to 5; 7 to
9; A, F
133
C6-03
(225)
Carrier Frequency
Upper Limit
CarrierFreq Max
Determines the upper and lower limits for the carrier frequency.
Carrier Frequency
E1-04
Max Output
Frequency
Output Frequency
× (C6-05) × K
Output
Frequency
C6-03
C6-04
Default:
<2>
Min.: 1.0 kHz
Max.: 12.5 kHz
171
C6-04
(226)
Carrier Frequency
Lower Limit
CarrierFreq Min
Default:
<2>
Min.: 1.0 kHz
Max.: 12.5 kHz
171
C6-05
(227)
Carrier Frequency
Proportional Gain
CarrierFreq Gain
Default:
<2>
Min.: 0
Max.: 99
171
<1> Default setting value is dependent on parameters A1-02, Control Method Selection and o2-04, Drive Model Selection.
<2> Default setting value is dependent on parameter C6-02, Carrier Frequency Selection.
B.3 C: Tuning