No. Name
User
Setting
E5-03 Motor Rated Current
E5-04 Number of Motor Poles
E5-05 Motor Stator Resistance
E5-06 Motor d-Axis Inductance
E5-07 Motor q-Axis Inductance
E5-09 Motor Induction Voltage Constant 1
E5-24 Motor Induction Voltage Constant 2
H1-01
Multi-Function Digital Input Terminal S1 Function
Selection
H1-02
Multi-Function Digital Input Terminal S2 Function
Selection
H1-03
Multi-Function Digital Input Terminal S3 Function
Selection
H1-04
Multi-Function Digital Input Terminal S4 Function
Selection
H1-05
Multi-Function Digital Input Terminal S5 Function
Selection
H1-06
Multi-Function Digital Input Terminal S6 Function
Selection
H1-07
Multi-Function Digital Input Terminal S7 Function
Selection
H2-01 Multi-Function Contact Output (terminal M1-M2)
H2-02
Multi-Function Contact Output 2 (terminal M3-
M4)
H2-03
Multi-Function Contact Output 3 (terminal M5-
M6)
H3-01 Terminal A1 Signal Level Selection
H3-02 Terminal A1 Function Selection
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-09 Terminal A2 Signal Level Selection
H3-10 Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
H3-13 Analog Input Filter Time Constant
H3-14 Analog Input Terminal Enable Selection
H3-16 Terminal A1 Offset
H3-17 Terminal A2 Offset
H4-01
Multi-Function Analog Output Terminal FM
Monitor Selection
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-03
Multi-Function Analog Output Terminal FM Bias
H4-04
Multi-Function Analog Output Terminal AM
Monitor Selection
H4-05
Multi-Function Analog Output Terminal AM Gain
No. Name
User
Setting
H4-06
Multi-Function Analog Output Terminal AM Bias
H4-07
Multi-Function Analog Output Terminal FM
Signal Level Selection
H4-08
Multi-Function Analog Output Terminal AM
Signal Level Selection
H5-01 Drive Slave Address
H5-02 Communication Speed Selection
H5-03 Communication Parity Selection
H5-04 Stopping Method After Communication Error (CE)
H5-05 Communication Fault Detection Selection
H5-06 Drive Transmit Wait Time
H5-07 RTS Control Selection
H5-08 Communication Protocol Selection
H5-09 CE Detection Time
H5-10
Unit Selection for MEMOBUS/Modbus Register
0025H
H5-11 Communications ENTER Function Selection
H5-12 Run Command Method Selection
H5-14 BACnet Device Object ID
H5-15 BACnet Device Object ID
L1-01 Motor Overload Protection Selection
L1-02 Motor Overload Protection Time
L1-03
Motor Overheat Alarm Operation Selection (PTC
input)
L1-04
Motor Overheat Fault Operation Selection (PTC
input)
L1-05 Motor Temperature Input Filter Time (PTC input)
L1-08 oL1 Current Level
L1-13 Continuous Electrothermal Operation Selection
L2-01 Momentary Power Loss Operation Selection
L2-02 Momentary Power Loss Ride-Thru Time
L2-03 Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Ramp
Time
L2-05 Undervoltage Detection Level (Uv1)
L2-06 KEB Deceleration Time
L2-07 KEB Acceleration Time
L2-08 Frequency Gain at KEB Start
L2-10 KEB Detection Time (Minimum KEB Time)
L2-11 DC Bus Voltage Setpoint during KEB
L2-29 KEB Method Selection
L3-01 Stall Prevention Selection during Acceleration
L3-02 Stall Prevention Level during Acceleration
L3-03 Stall Prevention Limit during Acceleration
L3-04 Stall Prevention Selection during Deceleration
L3-05 Stall Prevention Selection during Run
L3-06 Stall Prevention Level during Run
L3-11 Overvoltage Suppression Function Selection
L3-17
Target DC Bus Voltage for Overvoltage
Suppression and Stall Prevention
L3-20 DC Bus Voltage Adjustment Gain
E.3 User Setting Table
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
383
E
Quick Reference Sheet

Table of Contents

Other manuals for YASKAWA Z1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Z1000 and is the answer not in the manual?

YASKAWA Z1000 Specifications

General IconGeneral
ModelZ1000
CategoryController
Humidity95% RH or less (non-condensing)
Control MethodV/F Control
Frequency Range400 Hz
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus
Operating Temperature-10 to 50°C
Storage Temperature-20 to 60°C
AltitudeUp to 1000 meters without derating
Cooling MethodForced Air
Enclosure RatingIP20
Voltage Class200V, 400V