Administrators Guide for SIP-T2 Series/T4 Series/T5 Series/CP920 IP Phones
168
To remove a function type, specify programmable key type IDs which start with the symbol “-. For
example, -14, 5, 2 means to remove “Intercom”, DND, Forward” types from the Dsskey function types
list. These programmable key types are not available when you configure programmable keys.
Note: Multiple programmable key type IDs are separated by commas. N/A” type is always kept.
Permitted
Values
blank or 0 (all valid function types are available);
Dsskey type IDs.
For supported Dsskey types and IDs, refer to Supported Dsskey Types.
Default Blank
Parameter
programablekey.X.type
[1]
<y0000000000xx>.cfg
Description It configures key feature for a specific programmable key.
Permitted
Values
0-N/A
2-Forward
5-DND
7-ReCall
8-SMS
9-Pick up
13-Speed Dial
14-Intercom
22-XML Group
23-Group Pickup
24-Multicast Paging
(Paging)
27-XML Browser
28-History
30-Menu
32-New SMS
33-Status
34-Hot Desking
38-LDAP (only appear
when ldap.enable =
1
40-Prefix
41-Zero Touch
43-Local Directory (Local Phonebook)
45-Local Group
47-XML Directory (XML Phonebook)
50-Phone Lock
51-Switch Account Up (not applicable to T19(P) E2)
52-Switch Account Down (not applicable to T19(P) E2)
61-Directory
66-Paging List
73-Custom Key (only appear when “features.enhanced_
dss_keys.enable = 1”)
85-Favorite (Local Favorite)
Note: The permitted values are configurable by programablekey.type_range.custom”.
Default
X=1, default: 28 - History
X=2, default: 61 - Directory
X=3, default: 5 DND
X=4, default: 30 - Menu
X=5, default: 28- History
X=6, default: 61- Directory
X=7, default: 51- Switch Account Up
X=8, default: 52- Switch Account Down
X=9, default: 33- Status
X=10, default: 0 - NA
X=11, default: 0 NA
X=12, default: 0 - NA
X=13, default: 0 NA
X=14, default: 2- Forward
X=17, default: 0 NA
X=18, default: 0 NA
Web UI Dsskey->Programmable Key->Type
Parameter
programablekey.X.history_type
[1]
<y0000000000xx>.cfg
Description It configures the history type of programmable key.
Permitted
0-Local History

Table of Contents