Chapter 5 EDITING AUTOMATIC SEARCH RESULTS
5-36
Changing the Splice Loss Threshold for Fault Events
The splice loss threshold for fault events cannot be changed if “NonDISPLAY” is
selected for “FAULT EVENT”.
1.
Locate the cursor to “SPLICE LOSS” for “AUTOSEARCH THRESHOLD VALUE”
by using the rotary knob or the arrow key.
2. Press [ENTER].
A selection window will appear.
3. Change to the desired splice loss threshold.
For method of changing the splice loss threshold, refer to page 3-42.
4.
Press [F1] (Re-SEARCH START).
Auto search will start with the newly set search conditions.
When changing the condition for two or more items, it is recommended to change
the condition for each item first and then press [F1].
Refer to the notes given on changing the search conditions (page 5-38).
Caution
Refer
TIP
Refer