Device Message
No. Function
Header
Numeric
Part
Description
5-14 Fiber end threshold EFL
(BPL)
m Sets the fiber end threshold.
3 m 10:1step
5-15 Fault event show/hide
setting
DFE m Shows/hides fault events.
m= 0: Shows fault events.
1: Hides fault events.
5-16 Fault event threshold
(Splice loss)
FESL m Sets the splice loss threshold for fault events.
0.01 m 9.99:0.01step
5-17 Fault event threshold
(Return loss)
FERL m Sets the return loss threshold for fault events.
20 m 70:1step
5-18 Auto search event count
output
No control command
5-19 Auto search result output No control command
5-20 Section analysis start point
setting
SSPOS
Sets the start point at the cursor position.
5-21 Section analysis end point
setting
SEPOS
Sets the end point at the cursor position.
5-22 Reference return loss
setting
AJPOS Sets the cursor position as the reference return
loss.
5-23 Section data acquisition No control command
6-1 Drive setting FDA m, n Sets the drive and file No.
m= 0: FD (expansion unit)
1: Built-in memory
2: -
3: PCMCIA
4: -
5: USB
n= File name (excluding file extension)
6-2 Folder setting DIR m Sets the folder name.
The device message must be separated from the
originating location using a comma “,”
m= Folder name (root folder sets “/”)
example:/aaa/bbb/ccc/ddd/
6-3 File type setting FF m Sets the file type.
m= 0: .TRB 6: .LST
1: - 7: .SOR(Telcordia)
2: .SET 8: .CSV
3: .SOR(Bellcore) 9: .TRD
4: .TIF 10: .TRA
5: .BMP 11: .4
(In file saveing, 3 and 7 will be not made
distinction)
6-4 Recorded capacity No control command
6-5 Recorded file name No control command
6-6 Sub folder check No control command
6-7 Acquisition of file list of
current folder
No control command
7-1 File recall FRC Recalls a file.
.BMP, .TIF, .LST, and .CSV files cannot be
recalled.
Drive (6-1), folder (6-2) and file type (6-3) must be
specified in advance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA AQ7260 OTDR and is the answer not in the manual?

YOKOGAWA AQ7260 OTDR Specifications

General IconGeneral
BrandYOKOGAWA
ModelAQ7260 OTDR
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals