SSI Interface 7 - 17
Host Serial Response Time-out
Parameter # 155 (SSI # 9Bh)
This parameter specifies how long the digital scanner waits for an ACK or NAK before resending. Also, if the
digital scanner wants to send, and the host has already been granted permission to send, the digital scanner
waits for the designated time-out before declaring an error.
To set the delay period (options are 2, 5, 7.5, or 9,9 seconds), scan one of the following bar codes.
NOTE Other values are available via SSI command.
*Low - 2 Seconds
(20)
Medium - 5 Seconds
(50)
High - 7.5 Seconds
(75)
Maximum - 9.9 Seconds
(99)