2 - 2 DS4308/DS4308P Digital Scanner Product Reference Guide
Beeper Definitions
The digital scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep
sequences that occur during both normal scanning and while programming the digital scanner.
Table 2-1
Beeper Definitions
Beeper Sequence Indication
Standard Use
Low/medium/high beeps Power up.
Short beep, tone
programmable
A bar code symbol was decoded (if decode beeper is enabled).
4 long low beeps Transmission error.
5 low beeps Conversion or format error.
Low/low/low/extra low beeps RS-232 receive error.
High beep The digital scanner detected a <BEL> character over RS-232.
Parameter Menu Scanning
Low/high beeps Input error; incorrect bar code, programming sequence, or
Cancel
scanned.
High/low beeps Keyboard parameter selected. Enter value using numeric bar codes.
High/low/high/low beeps Successful program exit with change in parameter setting.
ADF Programming
Low/low beeps Enter another alphabetic character or scan the
End of Message
bar code.
Low/high/high beeps All rules are deleted.
Low/high/low/high beeps Out of rule memory. Erase some existing rules, then try to save rule again.
Low/high/low beeps Cancel rule entry. Rule entry mode exited because of an error or the user
asked to exit rule entry.
Low/high beeps Entry error, wrong bar code scanned, or criteria/action list is too long for a rule.
Re-enter criterion or action.
Low beep Delete last saved rule. The current rule is left intact.
High/high beeps ADF criteria or action is expected. Enter another criterion or action, or scan the
Save Rule
bar code.
High/low/low beeps All criteria or actions cleared for current rule, continue entering rule.
High/low/high/low beeps Rule saved. Rule entry mode exited.
Code 39 Buffering
Low/high/low beeps The Code 39 buffer was erased or there was an attempt to clear or transmit an
empty buffer.
High/low beeps New Code 39 data was entered into the buffer.
3 long high beeps Code 39 buffer is full.

Table of Contents

Other manuals for Zebra DS4308

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS4308 and is the answer not in the manual?

Zebra DS4308 Specifications

General IconGeneral
SealingIP42
ConnectivityUSB, RS232, Keyboard Wedge, TGCS (IBM) 46XX over RS485
Decode Capability1D, 2D, PDF417
Drop SpecificationWithstands multiple 1.5 m (5 ft) drops to concrete
Operating Temperature32° to 104° F/0° to 40° C
Storage Temperature-40° to 158° F/-40° to 70° C
Humidity5% to 95% (non-condensing)
Weight5.7 oz./161.9 g
Dimensions6.5 in. H x 2.6 in. W x 3.6 in. D 16.5 cm H x 6.6 cm W x 9.1 cm D