11 - 70 DS4308/DS4308P Digital Scanner Product Reference Guide
GS1 DataBar Expanded
Parameter # 340 (SSI # F0h 54h)
Convert GS1 DataBar to UPC/EAN
Parameter # 397 (SSI # F0h, 8Dh)
This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols not decoded as part of a
Composite symbol. Enable this to strip the leading '010' from DataBar-14 and DataBar Limited symbols
encoding a single zero as the first digit, and report the bar code as EAN-13.
For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and
reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and
country code applies to converted bar codes. Note that neither the system character nor the check digit can be
stripped.
*Enable GS1 DataBar Expanded
(1)
Disable GS1 DataBar Expanded
(0)
Enable Convert GS1 DataBar to UPC/EAN
(1)
*Disable Convert GS1 DataBar to UPC/EAN
(0)