4 - 2 DS4308/DS4308P Digital Scanner Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high,
scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-10. The digital scanner
issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning
several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences/Miscellaneous Options Parameter Defaults
Table 4-1 lists defaults for user preferences parameters. To change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, see Default Parameters on page 4-5.
Configure the digital scanner using the 123Scan
2
configuration program (see Chapter 15, 123Scan2).
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 4-1
User Preferences Parameter Defaults
Parameter
Parameter
Number
1
SSI
Number
2
Default
Page
Number
User Preferences
Set Default Parameter Restore Defaults
4-5
Parameter Bar Code Scanning 236 ECh Enable
4-6
Beep on Decode 56 38h Enable
4-7
Direct Decode Indicator 859 F2h 5Bh Disable
4-8
Beeper Volume 140 8Ch High
4-9
Beeper Tone 145 91h Medium
4-10
Beeper Duration 628 F1h 74h Medium
4-11
Suppress Power Up Beeps 721 F1h D1h Do Not Suppress
4-11
Decode Pager Motor
(DS4308-HC and DS4308-XD)
613 F1h 65h Disable
4-12
1. Parameter number decimal values are used for programming via RSM commands.
2. SSI number hex values are used for programming via SSI commands.

Table of Contents

Other manuals for Zebra DS4308

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS4308 and is the answer not in the manual?

Zebra DS4308 Specifications

General IconGeneral
SealingIP42
ConnectivityUSB, RS232, Keyboard Wedge, TGCS (IBM) 46XX over RS485
Decode Capability1D, 2D, PDF417
Drop SpecificationWithstands multiple 1.5 m (5 ft) drops to concrete
Operating Temperature32° to 104° F/0° to 40° C
Storage Temperature-40° to 158° F/-40° to 70° C
Humidity5% to 95% (non-condensing)
Weight5.7 oz./161.9 g
Dimensions6.5 in. H x 2.6 in. W x 3.6 in. D 16.5 cm H x 6.6 cm W x 9.1 cm D