User Preferences & Miscellaneous Options 4 - 3
Decode Pager Motor Duration
(DS4308-HC and DS4308-XD)
626 F1h 72h 150 msec
4-12
Night Mode Trigger (DS4308-HC Only) 1215 F8h 04h BFh Enable
4-15
Night Mode Toggle (DS4308-HC Only) N/A N/A N/A
4-15
Low Power Mode 128 80h Disable
4-16
Time Delay to Low Power Mode 146 92h 1 Hour
4-17
Hand-Held Trigger Mode 138 8Ah Auto Aim
4-19
Hands-Free Mode 630 F1h 76h Enable
4-20
Presentation Performance Mode 650 F1h 8Ah Standard
4-21
Hands-Free/Hand-Held Auto Switching
(DS4308P Only)
N/A N/A Auto Aim in Hand-Held,
Auto Switching to
Hands-Free Enabled
4-22
Hand-Held Decode Aiming Pattern 306 F0h 32h Enable
4-23
Hands-Free (Presentation) Decode
Aiming Pattern
590 F1h 4Eh Enable Hands-Free
(Presentation) Decode
Aiming Pattern on PDF
DS4308-XD only
:
Enable Hands-Free
Decode Aiming Pattern
4-24
Hands-Free Motionless Timeout
(DS4308P Only)
745 F1h E9h 2.0 seconds
4-24
Motion Detect Range (DS4308P Only) 827 F2h 3Bh Full
4-25
Picklist Mode 402 F0h 92h Disabled Always
4-26
Continuous Bar Code Read 649 F1h 89h Disable
4-27
Unique Bar Code Reporting 723 F1h D3h Enable
4-27
Decode Session Timeout 136 88h 9.9 Sec
4-28
Timeout Between Decodes, Same
Symbol
137 89h 0.5 Sec
4-28
Timeout Between Decodes, Different
Symbols
144 90h 0.1 sec
4-29
Fuzzy 1D Processing 514 F1h 02h Enable
4-29
Decode Mirror Images (Data Matrix Only) 537 F1h 19h Auto
4-30
Mobile Phone/Display Mode 716 F1h CCh Normal
4-31
Table 4-1
User Preferences Parameter Defaults (Continued)
Parameter
Parameter
Number
1
SSI
Number
2
Default
Page
Number
1. Parameter number decimal values are used for programming via RSM commands.