3 - 2 DS4308/DS4308P Digital Scanner Product Reference Guide
Daily Cleaning and Disinfecting
Following are the cleaning and disinfecting instructions for environments that require daily or more frequent
cleaning to prevent the spread of germs, including healthcare workers who need to disinfect their scanner after
each patient visit and retail and other shift workers who share devices.
1. Dampen a soft cloth with one of the approved cleaning agents listed above or use pre-moistened wipes.
2. Gently wipe all surfaces, including the front, back, sides, top and bottom. Never apply liquid directly to the
scanner. Be careful not to let liquid pool around the scanner window, trigger, cable connector or any other
area on the device.
3. Be sure to clean the trigger and in between the trigger and the housing (use a cotton-tipped applicator to
reach tight or inaccessible areas).
4. Immediately dry the scanner window after cleaning with a soft non-abrasive cloth to prevent streaking.
5. Allow the unit to air dry before use.
Monthly 'Deep Cleaning' Maintenance
Keep your scanner in good working order with a regular comprehensive cleaning routine to remove the natural
build-up of dirt that occurs with everyday use on connectors and the scanner exit window as well as, the main
surfaces of the device.
1. Housing: Follow the instructions for daily cleaning and disinfecting above to give the housing a general
cleaning.
2. Scanner window: Wipe the scanner window with a lens tissue or other material suitable for cleaning optical
material such as eyeglasses.
3. Scanner connector:
a. Dip the cotton portion of a cotton-tipped applicator in isopropyl alcohol.
b. Rub the cotton portion of the cotton-tipped applicator back-and-forth across the connector on the
scanner. Do not leave any cotton residue on the connector.
c. Repeat at least 3 times.
d. Use the cotton-tipped applicator dipped in alcohol to remove any grease and dirt near the connector
area.
e. Use a dry cotton tipped applicator and repeat steps c, d and e (do not apply alcohol as directed in any
of these steps).

Table of Contents

Other manuals for Zebra DS4308

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS4308 and is the answer not in the manual?

Zebra DS4308 Specifications

General IconGeneral
SealingIP42
ConnectivityUSB, RS232, Keyboard Wedge, TGCS (IBM) 46XX over RS485
Decode Capability1D, 2D, PDF417
Drop SpecificationWithstands multiple 1.5 m (5 ft) drops to concrete
Operating Temperature32° to 104° F/0° to 40° C
Storage Temperature-40° to 158° F/-40° to 70° C
Humidity5% to 95% (non-condensing)
Weight5.7 oz./161.9 g
Dimensions6.5 in. H x 2.6 in. W x 3.6 in. D 16.5 cm H x 6.6 cm W x 9.1 cm D